ASTM International - ASTM E336-17a

Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings

inactive
Buy Now
Organization: ASTM International
Publication Date: 15 November 2017
Status: inactive
Page Count: 15
ICS Code (Acoustics in building. Sound insulation): 91.120.20
significance And Use:

5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the sound transmission loss of partitions. These procedures assume that the rooms in which... View More

scope:

1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number of indirect paths, usually referred to as flanking paths. Fig. 1 illustrates the direct paths (D) and some possible structural flanking paths (F). Additional non-structural flanking paths may include transmission through common air ducts between rooms, or doors to the corridor from adjacent rooms. Sound isolation is also influenced by the size of the separating partition between spaces and absorption in the receiving space, and in the case of small spaces by modal behavior of the space and close proximity to surfaces.

FIG. 1 Direct (D) and Some Indirect or Flanking Paths (F and Dotted) in a Building

1.2 The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions thereof in a building separated by a common partition or the apparent sound insulation of the separating partition, including both direct and flanking transmission paths in all cases. Appropriate measures and their single number ratings are the noise reduction (NR) and noise isolation class (NIC) which indicate the isolation with the receiving room furnished as it is during the test, the normalized noise reduction (NNR) and normalized noise isolation class (NNIC) which indicate the expected isolation when the receiving room is a normally furnished living or office space that is at least 25 m3 (especially useful when the test must be done with the receiving room unfurnished), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC) which indicate the apparent sound insulating properties of a separating partition including both the direct transmission and flanking transmission through the support structure. The measurement of ATL is limited to spaces of at least 25 m3 where modal effects create fewer problems. With the exception of the ATL and ASTC under specified conditions, these procedures in the main part of the test method are only applicable when both room volumes are less than 150 m3.

Note 1: The word "partition" in this test method includes all types of walls, floors, or any other boundaries separating two spaces. The boundaries may be permanent, operable, or movable.

1.3 The NR and NIC between two locations may always be measured and reported though conditions present will influence how measurements are made. Restrictions such as minimum room volume or dimensions or maximum room absorption are imposed for all other measures and ratings in this standard. Thus, conditions may exist that will not allow NNR (NNIC) or ATL (ASTC) to be reported. Where a partition between rooms is composed of parts that are constructed differently, or contains an element such as a door, it is not possible to measure the ATL and ASTC of the individual elements or portions of the partition. To evaluate the field performance of a door less than 6 m2 in area, use Test Method E2964. The various metrics are inherently different quantities, so that NIC cannot be used instead of NNIC or ASTC when specifications are written in terms of one of those metrics that cannot be reported with the conditions present.

1.4 Annex A1 provides methods to measure the sound isolation between portions of two rooms in a building separated by a common partition including both direct and flanking paths when at least one of the rooms has a volume of 150 m3 or more. The results are the noise reduction (NR) and noise isolation class (NIC).

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 The text of this test method references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.7 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

January 1, 2023
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally...
April 1, 2020
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally...
October 1, 2019
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally...
January 1, 2019
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally...
ASTM E336-17a
November 15, 2017
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally...
July 1, 2017
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
October 1, 2016
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
January 1, 2016
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
September 1, 2015
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
April 15, 2014
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
November 1, 2011
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
September 1, 2010
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
September 1, 2009
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
November 1, 2008
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
The main part of this standard uses procedures originally developed for laboratory measurements of the transmission loss of partitions. These procedures assume that the rooms in which the...
October 1, 2007
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1.1 The sound isolation between two spaces in a building is determined by a combination of the direct transmission through the nominally separating building element (as normally measured in a...
April 1, 2005
Standard Test Method for Measurement of Airborne Sound Insulation in Buildings
1.1 The sound isolation between two spaces in a building is determined by a combination of the direct transmission through the nominally separating building element (as normally measured in a...
March 10, 1997
Standard Test Method for Measurement of Airborne Sound Insulation in Buildings
1.1 Measures of Acoustical Insulation- This test method covers procedures for determining the sound insulation between two rooms in a building. The evaluation may be made including all paths by which...
March 10, 1997
Standard Test Method for Measurement of Airborne Sound Insulation in Buildings
1.1 Measures of Acoustical Insulation- This test method covers procedures for determining the sound insulation between two rooms in a building. The evaluation may be made including all paths by which...
Advertisement