ASTM International - ASTM E388-04(2015)

Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 May 2015
Status: inactive
Page Count: 3
ICS Code (Optical measuring instruments): 17.180.30
scope:

1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier tube detection. This test method can be applied to instruments that use multi-element detectors, such as diode arrays, but results must be interpreted carefully. This test method uses atomic lines between 250 nm and 1000 nm.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

abstract:

This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier... View More

Document History

January 1, 2023
Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers
1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier...
ASTM E388-04(2015)
May 1, 2015
Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers
1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier...
October 1, 2009
Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers ,
1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier...
November 1, 2004
Standard Test Method for Wavelength Accuracy of Spectral Bandwidth Fluorescence Spectrometers
1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier...
October 10, 1998
Standard Test Method for Spectral Bandwidth and Wavelength Accuracy of Fluorescence Spectrometers
1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers.