ASTM International - ASTM C687-02

Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation

inactive
Buy Now
Organization: ASTM International
Publication Date: 10 December 2002
Status: inactive
Page Count: 10
ICS Code (Thermal insulation of buildings): 91.120.10
scope:

1.1 This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations at mean temperatures between -20 and 55°C (4 to 131°F).

1.2 This practice applies to a wide variety of loose-fill thermal insulation products including fibrous glass, rock/slag wool, or cellulosic fiber materials; granular types including vermiculite and perlite; pelletized products; and any other insulation material that may be installed pneumatically or poured in place. It does not apply to products that change their character after installation either by chemical reaction or the application of binders or adhesives, nor does it consider the effects of structures, containments, facings, or air films.

1.3 Since this practice is designed for reproducible product comparison, it measures the thermal resistance of an insulation material which has been preconditioned to a relatively dry state. Consideration of changes of thermal performance of a hygroscopic insulation by sorption of water is beyond the scope of this practice.

1.4 The sample preparation techniques outlined in this practice do not cover the characterization of loose-fill materials intended for enclosed applications. For those applications, a separate sample preparation technique that simulates the installed condition will be required. For those applications, however, other aspects of this practice should be applicable.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

September 1, 2018
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
4.1 The thermal resistance, R, of an insulation is used to describe its thermal performance. 4.2 The thermal resistance of an insulation is related to the density and thickness of the insulation. It...
March 15, 2017
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
4.1 The thermal resistance, R, of an insulation is used to describe its thermal performance. 4.2 The thermal resistance of an insulation is related to the density and thickness of the insulation. It...
September 1, 2012
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
4.1 The thermal resistance, R, of an insulation is used to describe its thermal performance. 4.2 The thermal resistance of an insulation is related to the density and thickness of the insulation. It...
November 15, 2007
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
The thermal resistance, R, of an insulation is used to describe its thermal performance. The thermal resistance of an insulation is related to the density and thickness of the insulation. It is...
May 1, 2005
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
1.1 This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations at mean temperatures between 20 and 55C (4 to 131F). 1.2 This practice applies to...
ASTM C687-02
December 10, 2002
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
1.1 This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations at mean temperatures between -20 and 55°C (4 to 131°F). 1.2 This practice applies...
March 10, 1996
Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
1.1 This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations at mean temperatures between -20 and 55°C (-4 to 131°F). 1.2 This practice...
Advertisement