ASTM International - ASTM D6918-09

Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 November 2009
Status: inactive
Page Count: 6
ICS Code (Roofs): 91.060.20
significance And Use:

This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains.

In case of dispute arising from differences in reported test results when... View More

scope:

1.1 This test method is a performance test that measures the effect crimping has on the ability of vertical strip drains to transmit water parallel to the plane of the drain.

1.2 This test method is applicable to all vertical strip drains.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

August 1, 2022
Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition
5.1 This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains. 5.1.1 In case of dispute arising from differences in reported test results when...
January 1, 2014
Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition
5.1 This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains. 5.1.1 In case of dispute arising from differences in reported test results when...
ASTM D6918-09
November 1, 2009
Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition
This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains. In case of dispute arising from differences in reported test results when using this...
June 1, 2007
Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition
This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains. 5.1.1 In case of dispute arising from differences in reported test results when using...
June 10, 2003
Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition
1.1 This test method is a performance test, which measures the effect crimping, has on the ability of vertical strip drains to transmit water parallel to the plane of the drain. 1.2 This test method...