ASTM International - ASTM G120-01(2008)

Standard Practice for Determination of Soluble Residual Contamination in by Soxhlet Extraction

inactive
Buy Now
Organization: ASTM International
Publication Date: 1 September 2008
Status: inactive
Page Count: 4
ICS Code (Chemical analysis): 71.040.40
significance And Use:

It is expected that this practicewill be suitable to identify and quantify contaminants found in systems, system materials, and components used in systems requiring a high level of cleanliness,... View More

scope:

1.1 This practice describes a procedure for the determination of residual contamination in systems and components requiring a high level of cleanliness, such as oxygen, by Soxhlet extraction.

1.2 This practice may be used for extracting nonvolatile and semivolatile residues from solids such as new and used gloves, new and used wipes, contaminated test specimens or control coupons, small pieces of hardware, component softgoods, etc. When used with proposed cleaning materials (wipes, gloves, etc.), from the cleaning materials this practice may be used to determine the potential of the proposed solvent to extract contaminants (plasticizers, residual detergents, brighteners, etc.) and deposit them on the surface being cleaned.

1.3 This practice is not suitable for the evaluation of particulate contamination.

1.4 The values stated in SI units are standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

March 1, 2023
Standard Practice for Determination of Soluble Residual Contamination by Soxhlet Extraction
5.1 It is expected that this practice will be suitable to identify and quantify contaminants found in systems, system materials, and components used in systems requiring a high level of cleanliness,...
October 1, 2015
Standard Practice for Determination of Soluble Residual Contamination by Soxhlet Extraction
5.1 It is expected that this practice will be suitable to identify and quantify contaminants found in systems, system materials, and components used in systems requiring a high level of cleanliness,...
ASTM G120-01(2008)
September 1, 2008
Standard Practice for Determination of Soluble Residual Contamination in by Soxhlet Extraction
It is expected that this practicewill be suitable to identify and quantify contaminants found in systems, system materials, and components used in systems requiring a high level of cleanliness, such...
September 10, 2001
Standard Practice for Determination of Soluble Residual Contamination in by Soxhlet Extraction
1.1 This practice describes a procedure for the determination of residual contamination in systems and components requiring a high level of cleanliness, such as oxygen, by Soxhlet extraction. 1.2...
September 10, 2001
Standard Practice for Determination of Soluble Residual Contamination in by Soxhlet Extraction
1.1 This practice describes a procedure for the determination of residual contamination in systems and components requiring a high level of cleanliness, such as oxygen, by Soxhlet extraction. 1.2...
September 10, 2001
Standard Practice for Determination of Soluble Residual Contamination in by Soxhlet Extraction
It is expected that this test method will be suitable to identify and quantify contaminants found in systems, system materials, and components used in systems requiring a high level of cleanliness,...